Siemens SINAMICS S110 - r1078 CO: Total setpoint effective; Total setpoint eff; p1080[0...n] Minimum speed; n_min; p1082[0...n] Maximum speed; n_max

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
List of parameters
1-200
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Displays the total effective setpoint. The value indicates the sum of the effective main setpoint and supplementary
setpoint.
Description: Sets the lowest possible motor speed.
This value is not undershot in operation.
Note: The parameter value applies for both motor directions.
In exceptional cases, the motor can operate below this value (e.g. when reversing).
Description: Sets the highest possible speed.
Dependency: Refer to: p0322, p0324, p0532
Notice: After the value has been modified, no further parameter modifications can be made and the status is shown in
r3996. Modifications can be made again when r3996 = 0.
Note: The parameter applies for both motor directions. The parameter has a limiting effect and is the reference quantity
for all ramp-up and ramp-down times (e.g. down ramps, ramp-function generator, motor potentiometer).
Since the parameter is part of quick commissioning (p0010 = 1), it is defined appropriately when p0310, p0311,
p0322, p0324, p0530, p0531, and p0532 are changed.
The following limits are always effective for p1082:
p1082 <= min(p0324, p0532) if p0324 > 0 and p0532 > 0
p1082 <= p0322 if p0324 = 0 or p0532 = 0 and p0322 > 0
p1082 <= 60 / (10.0 * p0115[0] * r0313)
p1082 <= 60 * Maximum power unit pulse frequency / (5.0 * r0313)
For the automatic calculation (p0340 = 1) the value of the parameter is pre-assigned the maximum motor speed
(p0322). If p0322 = 0, the rated motor speed (p0311) is used as default (pre-assignment) value. For induction
motors that are not catalog motors (p0301 = 0), the synchronous no-load speed is used as default (pre-assignment)
value (p0310 * 60 / r0313).
r1078 CO: Total setpoint effective / Total setpoint eff
SERVO_S110-CAN
(Extended set),
SERVO_S110-DP
(Extended set),
SERVO_S110-PN
(Extended set)
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: 3030
P-Group: Setpoints Units group: 3_1 Unit selection: p0505
Not for motor type: - Scaling: p2000 Expert list: 1
Min Max Factory setting
- [rpm] - [rpm] - [rpm]
p1080[0...n] Minimum speed / n_min
SERVO_S110-CAN
(Extended set),
SERVO_S110-DP
(Extended set),
SERVO_S110-PN
(Extended set)
Can be changed: C2(1), T Calculated: - Access level: 1
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: 3050
P-Group: Setpoints Units group: 3_1 Unit selection: p0505
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.000 [rpm] 19500.000 [rpm] 0.000 [rpm]
p1082[0...n] Maximum speed / n_max
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C2(1), T Calculated: CALC_MOD_ALL Access level: 1
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: 3020, 3050,
3060, 3070, 3095, 5300
P-Group: Setpoints Units group: 3_1 Unit selection: p0505
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.000 [rpm] 210000.000 [rpm] 1500.000 [rpm]