SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Rotor resistance for an induction motor determined by the motor data identification.
This stator resistance can be changed after the identification and accepted in p0354 with p1910/p1960 = -3.
Dependency: Refer to: p0354, p0625, p1910, r1927, p1960
Note: The parameter is not used for synchronous motors (p0300 = 2xx).
Description: Stator leakage inductance determined by the motor data identification.
This stator leakage inductance can be changed after the identification and accepted in p0356 with p1910/p1960 = -
3.
Dependency: Refer to: p0356, p1910, r1932
Description: Rotor leakage induction for an induction motor determined by the motor data identification.
This rotor leakage inductance can be changed after the identification and accepted in p0358 with p1910/p1960 = -3.
Dependency: Refer to: p0358, p1910, r1932
Description: Magnetizing inductance for an induction motor determined by the motor data identification.
This magnetizing inductance can be changed after the identification and accepted in p0360 with p1910/p1960 = -3.
Dependency: Refer to: p0360, p1910, r1936, p1960
p3054[0...n] MotId rotor resistance identified / R_rotor ident
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: FloatingPoint32 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor identification Units group: 16_1 Unit selection: p0349
Not for motor type: PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
0.00000 [ohm] 300.00000 [ohm] 0.00000 [ohm]
p3056[0...n] MotId stator leakage inductance identified / L_stator leak
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: FloatingPoint32 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor identification Units group: 15_1 Unit selection: p0349
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00000 [mH] 1000.00000 [mH] 0.00000 [mH]
p3058[0...n] MotId rotor leakage inductance identified / L_rotor leak
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: FloatingPoint32 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor identification Units group: 15_1 Unit selection: p0349
Not for motor type: PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
0.00000 [mH] 1000.00000 [mH] 0.00000 [mH]
p3060[0...n] MotId magnetizing inductance identified / MotId Lh ident
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: FloatingPoint32 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor identification Units group: 15_1 Unit selection: p0349
Not for motor type: PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
0.00000 [mH] 10000.00000 [mH] 0.00000 [mH]