EasyManua.ls Logo

Siemens SINAMICS S110 - p10047 SI F-DO test stop mode; SI F­DO test mode; r10049 SI F-DI monitoring status (processor 1); SI F­DI status P1

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
List of parameters
1-632
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Dependency: Refer to: p10001, p10003, p10007, p10047
Note: The test stop is only performed if the safety output of the Control Unit is being used (see p10042).
Description: Sets the test stop mode for the safety digital output (F-DO)
Value: 1: Test mode 1 evaluation of int. diagnostic signal (passive load)
2: Test mode 2 read back F-DO in DI (relay circuit)
3: Test mode 3 read back F-DO in DI (actuator with feedback signal)
Dependency: Refer to: p10001, p10003, p10007, p10046
Note: The test stop is only performed if the safety output is being used (see p10042).
Description: Displays the monitoring status of the fail-safe digital inputs (F-DI).
The F-DIs that are being used by the Safety Integrated functions are displayed.
If the module used has fewer than 3 F-DIs, "Freely available" is displayed for the F-DIs which are not in use.
Dependency: p10006 / p10106
p10022 / p10122
p10023 / p10123
p10024 / p10124
p10025 / p10125
p10026 / p10126
p10027 / p10127
p10028 / p10128
p10030 / p10130
p10031 / p10131
p10036 / p10136
p10050 / p10150
Refer to: r10149
Bit field: Bit Signal name 1 signal 0 signal FP
00 Test F-DO 0 Test active No test -
p10047 SI F-DO test stop mode / SI F-DO test mode
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C2(95) Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0001 bin 0011 bin 0010 bin
r10049 SI F-DI monitoring status (processor 1) / SI F-DI status P1
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 F-DI 0 Safety monitored Freely available -
01 F-DI 1 Safety monitored Freely available -
02 F-DI 2 Safety monitored Freely available -

Table of Contents

Other manuals for Siemens SINAMICS S110

Related product manuals