Description: Displays the actual value at the digital inputs.
This means that the actual input signal can be checked at terminal DI x or DI/DO x prior to switching from the simu-
lation mode (p0795.x = 1) to terminal mode (p0795.x = 0).
Note: If a DI/DO is parameterized as output (p0728.x = 1), then r0721.x = 0 is displayed.
DI: Digital Input
DI/DO: Bidirectional Digital Input/Output
Description: Displays the status of the digital inputs.
r0721 CU digital inputs, terminal actual value / CU DI actual value
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 2
Data type: Unsigned32 Dynamic index: - Func. diagram: 1510, 2020,
2030, 2031, 2100, 2120, 2130,
2131, 2132, 2133
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (X133.1) High Low -
01 DI 1 (X133.2) High Low -
02 DI 2 (X133.3) High Low -
03 DI 3 (X133.4) High Low -
08 DI/DO 8 (X132.1) High Low -
09 DI/DO 9 (X132.2) High Low -
10 DI/DO 10 (X132.3) High Low -
11 DI/DO 11 (X132.4) High Low -
16 DI 16 (X130.1) High Low -
17 DI 17 (X130.2) High Low -
18 DI 18 (X130.4) High Low -
19 DI 19 (X130.5) High Low -
20 DI 20 (X131.1) High Low -
21 DI 21 (X131.2) High Low -
22 DI 22 (X131.4) High Low -
r0722.0...22 CO/BO: CU digital inputs, status / CU DI status
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: 1510, 2020,
2030, 2031, 2100, 2120, 2130,
2131, 2132, 2133
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (X133.1) High Low -
01 DI 1 (X133.2) High Low -
02 DI 2 (X133.3) High Low -
03 DI 3 (X133.4) High Low -
08 DI/DO 8 (X132.1) High Low -
09 DI/DO 9 (X132.2) High Low -
10 DI/DO 10 (X132.3) High Low -
11 DI/DO 11 (X132.4) High Low -
16 DI 16 (X130.1) High Low -
17 DI 17 (X130.2) High Low -
18 DI 18 (X130.4) High Low -
19 DI 19 (X130.5) High Low -
20 DI 20 (X131.1) High Low -