List of parameters
Parameter
1-155
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Sets the physical address to output signals via the test sockets.
Index: [0] = T0
[1] = T1
[2] = Reserved
Dependency: Changes only become effective if p0776 does not equal 99.
Refer to: p0789, r0790
Description: Sets the gain of a signal output of a physical address via test sockets.
Index: [0] = T0
[1] = T1
[2] = Reserved
Dependency: Changes only become effective if p0776 does not equal 99.
Refer to: p0788
Description: Displays the actual value of a signal determined via a physical address.
Index: [0] = T0
[1] = T1
[2] = Reserved
Dependency: Only effective when p0776 = 97 or p0776 = 96.
Refer to: p0788
p0788[0...2] Test sockets physical address / Test skt PhyAddr
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 4
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0000 bin 1111 1111 1111 1111 1111 1111
1111 1111 bin
0000 bin
p0789[0...2] Test sockets physical address gain / TestSktPhyAddrGain
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 4
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-340.28235E36 340.28235E36 1.00000
r0790[0...2] Test sockets physical address signal value / TestSktsPhyAddrVal
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -