Description: Sets the input mode for the safety digital inputs (F-DI).
Note: Only an NC contact can be connected for the safety digital inputs not listed.
Description: Sets the signal sources for F-DO 0 (X131.5).
The 6 signal sources in p10042[0...5] are AND'ed and the result is output at F-DO 0.
Value: 0: No function
1: STO active
2: SS1 active
3: SS2 active
4: SOS active
5: SLS active
6: SSM feedback signal active
7: Safe state
8: SOS selected
9: Internal event
10: Active SLS stage bit 0
11: Active SLS stage bit 1
12: SDI positive active
13: SDI negative active
Index: [0] = AND logic operation input 1
[1] = AND logic operation input 2
[2] = AND logic operation input 3
[3] = AND logic operation input 4
[4] = AND logic operation input 5
[5] = AND logic operation input 6
Note: F-DO: Failsafe Digital Output
Description: Activates the readback input for the safety digital output (F-DO)
The test mode for the particular safety digital output is set in p10047.
p10040 SI F-DI input mode / SI F-DI inp_mode
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C2(95) Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 F-DI 1 (X130.2) NO contact NC contact 2850
01 F-DI 2 (X130.5) NO contact NC contact 2850
02 F-DI 3 (X131.2) NO contact NC contact 2850
p10042[0...5] SI F-DO 0 signal sources / SI F-DO 0 S_src
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C2(95) Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: 2857
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 13 0
p10046 SI F-DO feedback signal input activation / SI F-DO FS act
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C2(95) Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0000 bin