Parameter
List of parameters
1-256
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Notice: A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Description: Displays the maximum torque/force generating current as a result if all current limits.
Description: Displays the upper torque limit of all torque limits.
Dependency: Refer to: p1520, p1521, p1522, p1523, p1528, p1529, p1532
Description: Displays the lower torque limit of all torque limits.
Dependency: Refer to: p1520, p1521, p1522, p1523, p1528, p1529, p1532
Description: Displays the currently effective upper torque limit.
Note: The effective upper torque limit is reduced with respect to the selected upper torque limit p1520, if the current limit
p0640 is reduced or the rated magnetizing current of the induction motor p0320 is increased.
The torque limit p1520 can be re-calculated using p0340 = 1, 3 or 5.
r1533 Current limit torque-generating total / Iq_max total
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: 5640, 5722,
6640
P-Group: Displays, signals Units group: 6_2 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r1534 CO: Torque limit upper total / M_max upper total
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: 1610, 5620,
5630, 5640
P-Group: Closed-loop control Units group: 7_1 Unit selection: p0505
Not for motor type: REL Scaling: p2003 Expert list: 1
Min Max Factory setting
- [Nm] - [Nm] - [Nm]
r1535 CO: Torque limit lower total / M_max lower total
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: 1610, 5620,
5630, 5640
P-Group: Closed-loop control Units group: 7_1 Unit selection: p0505
Not for motor type: REL Scaling: p2003 Expert list: 1
Min Max Factory setting
- [Nm] - [Nm] - [Nm]
r1538 CO: Upper effective torque limit / M_max upper eff
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dynamic index: - Func. diagram: 1590, 1610,
5610, 5650
P-Group: Closed-loop control Units group: 7_1 Unit selection: p0505
Not for motor type: REL Scaling: p2003 Expert list: 1
Min Max Factory setting
- [Nm] - [Nm] - [Nm]