List of parameters
Parameter
1-431
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Sets the time constant of the PT1 element to smooth the torque actual value.
The smoothed actual torque is compared with the threshold values and is only used for messages and signals.
Description: Sets the monitoring time for phase failure detection of the motor.
Notice: After the value has been modified, no further parameter modifications can be made and the status is shown in
r3996. Modifications can be made again when r3996 = 0.
Note: For p3235 = 0 the function is deactivated.
Description: Settings for start/stop and the comparison type for the variable signaling function.
Description: Sets the signal source for the variable signaling function.
Dependency: Refer to: p3292, p3293
Note: Re p3291 = 1:
In this case, the signal source is defined using p3292 and p3293.
p3233[0...n] Torque actual value filter, time constant / M_act_filt T
SERVO_S110-CAN
(Ext msg),
SERVO_S110-DP
(Ext msg),
SERVO_S110-PN
(Ext msg)
Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: 8013
P-Group: Messages Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 [ms] 1000000 [ms] 0 [ms]
p3235 Phase failure signal motor monitoring time / Ph_fail t_monit
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: - Access level: 4
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Messages Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 [ms] 2000 [ms] 320 [ms]
p3290 Variable signaling function start / Var sig start
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned8 Dynamic index: - Func. diagram: 5301
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0010 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Activate function Active Not active -
01 Comparison with sign With sign Without sign -
p3291 CI: Variable signaling function signal source / Var sig S_src
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 / Integer16 Dynamic index: - Func. diagram: 5301
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0