List of parameters
Parameter
1-139
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Displays the rotor temperature of the motor temperature model.
Description: Sets the current limit.
Dependency: Refer to: r0209, p0323
Note: The parameter is part of the quick commissioning (p0010 = 1); this means that it is appropriately pre-assigned when
changing p0305, p0323 and p0338.
The current limit p0640 is limited to r0209 and p0323. The limit to p0323 is not realized if a value of zero is entered
there.
The resulting current limit is displayed in r0067 and if required, r0067 is reduced by the thermal model of the Motor
Module.
The torque and power limits (p1520, p1521, p1530, p1531) matching the current limit are automatically calculated
when exiting the quick commissioning using p3900 > 0 or using the automatic parameterization with p0340 = 3, 5.
For VECTOR the following applies (p0107):
p0640 is limited to 4.0 x p0305.
p0640 is pre-assigned for the automatic self commissioning routine (e.g. to 1.5 x p0305, with p0305 = r0207[1]).
p0640 must be entered when commissioning the system. This is the reason that p0640 is not calculated by the
automatic parameterization when exiting the quick commissioning (p3900 > 0).
For SERVO the following applies (p0107):
p0640 is pre-assigned as follows using the automatic parameterization (p0340 = 1, p3900 > 0) taking into account
the limits r0209 and r0323:
- for induction motors: p0640 = 1.5 x p0305
- for synchronous motors: p0640 = p0338
Description: Sets the reduction for the current limit in encoderless operation.
The value is referred to p0640.
Dependency: Refer to: r0209, p0323, p0491, p0640, p1300, p1404
Note: If the motor is operated both with encoder as well as without encoder (e.g. p0491 is not equal to 0 or p1404 <
p1082) then the maximum current can be reduced in encoderless operation. This reduces disturbing saturation-
related motor data changes in encoderless operation.
r0633[0...n] Motor temperature model, rotor temperature / MotTMod T_rotor
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dynamic index: MDS, p0130 Func. diagram: 8016
P-Group: Motor Units group: 21_1 Unit selection: p0505
Not for motor type: PEM, REL, FEM Scaling: p2006 Expert list: 1
Min Max Factory setting
- [°C] - [°C] - [°C]
p0640[0...n] Current limit / Current limit
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C2(1, 3), U, T Calculated: CALC_MOD_ALL Access level: 2
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: 5722, 6640
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [Arms] 10000.00 [Arms] 0.00 [Arms]
p0642[0...n] Encoderless operation current reduction / Encoderl op I_red
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C2(1, 3), U, T Calculated: - Access level: 1
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [%] 100.00 [%] 100.00 [%]