EasyManua.ls Logo

Siemens SINAMICS S110 - r4776[0...16383] Trace 1 trace buffer signal 6; Trace 1 trace sig6; r4777[0...16383] Trace 1 trace buffer signal 7; Trace 1 trace sig7; p4780[0...1] Trace physical address signal 0; Trace PhyAddr Sig0; p4781[0...1] Trace physical address signal 1; Trace PhyAddr Sig1

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
List of parameters
1-466
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Displays the trace buffer (record buffer) for trace 1 and signal 6.
Dependency: Refer to: r4760
Description: Displays the trace buffer (record buffer) for trace 1 and signal 7.
Dependency: Refer to: r4760
Description: Sets the physical address for the first signal to be traced.
The data type is defined using p4730.
Index: [0] = Trace 0
[1] = Trace 1
Description: Sets the physical address for the second signal to be traced.
The data type is defined using p4731.
Index: [0] = Trace 0
[1] = Trace 1
r4776[0...16383] Trace 1 trace buffer signal 6 / Trace 1 trace sig6
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r4777[0...16383] Trace 1 trace buffer signal 7 / Trace 1 trace sig7
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
p4780[0...1] Trace physical address signal 0 / Trace PhyAddr Sig0
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0000 bin 1111 1111 1111 1111 1111 1111
1111 1111 bin
0000 bin
p4781[0...1] Trace physical address signal 1 / Trace PhyAddr Sig1
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0000 bin 1111 1111 1111 1111 1111 1111
1111 1111 bin
0000 bin

Table of Contents

Other manuals for Siemens SINAMICS S110

Related product manuals