Siemens SINAMICS S110 - r1432 CO: Speed pre-control after symmetrizing; n_prectr after sym; p1433[0...n] Speed controller reference model natural frequency; n_ctrl RefMod fn; p1434[0...n] Speed controller reference model damping; n_ctrl RefMod D; p1435[0...n] Speed controller reference model dead time; n_ctrRefMod t_dead

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameter
1-241
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Displays the speed pre-control value after symmetrizing for the torque build-up (emulates the closed current control
loop).
Dependency: Symmetrizing can be parameterized with p1428 and/or p1429.
Description: Sets the natural frequency of a PT2 element for the reference model of the speed controller.
Recommend.: The reference model is correctly set when the characteristics of p1439 (reference model output) and p1445 (actual
speed value) are virtually identical when the I component of the speed controller is disabled.
Dependency: Together with p1434 and p1435, the characteristics (in the time domain) of the closed-loop speed control (P) can be
emulated.
For VECTOR (r0107) the following applies:
The reference model is activated with p1400.3 = 1. For sensorless vector control (p1300 = 20) the reference model
is disabled in open-loop speed controlled operation (refer to p1755).
Refer to: p1434, p1435
Description: Sets the damping of a PT2 element for the reference model of the speed controller.
Recommend.: The reference model is correctly set when the characteristics of p1439 (reference model output) and p1445 (actual
speed value) are virtually identical when the I component of the speed controller is disabled.
Dependency: In conjunction with p1433 and p1435, the characteristics (in time) of the P-controlled speed control loop can be
emulated.
For VECTOR (r0107) the following applies:
The reference model is activated with p1400.3 = 1.
Refer to: p1433, p1435
Description: Sets the "fractional" dead time for the reference model of the speed controller.
r1432 CO: Speed pre-control after symmetrizing / n_prectr after sym
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: 5030
P-Group: Closed-loop control Units group: 3_1 Unit selection: p0505
Not for motor type: REL Scaling: p2000 Expert list: 1
Min Max Factory setting
- [rpm] - [rpm] - [rpm]
p1433[0...n] Speed controller reference model natural frequency / n_ctrl RefMod fn
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: 5030, 6031
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.0 [Hz] 8000.0 [Hz] 0.0 [Hz]
p1434[0...n] Speed controller reference model damping / n_ctrl RefMod D
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: 5030, 6031
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.000 5.000 1.000
p1435[0...n] Speed controller reference model dead time / n_ctrRefMod t_dead
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: 5030, 6031
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.00 2.00 0.00