EasyManua.ls Logo

Siemens SINAMICS S110 - Fig. 2-83 2846 - Extended Functions, parameter manager

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function diagrams
Safety Integrated
2-844
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-83 2846 – Extended Functions, parameter manager
- 2846 -
Function diagram
87654321
fp_2846_98_eng.vsd
DO: SERVO
SINAMICS S110Safety Integrated - Extended Functions, Parametermanager
Changing Safety parameters
SI password input
p9761
Resetting safety parameters
Disabling Safety functions
x
p9500 (12.00 ms)
14.09.10 V04.04.00
Safety parameter
p9300 … p9399
p9500 … p9599
can be reset to
factory settings via
p0970, p3900
Safety parameter
p9300 … p9399
p9500 … p9599
p10000 ... p10199
can be changed
SI password new
p9762
SI ackn password
p9763
Safety parameterization enable
y
<1>
<1>
Effective password
=
Password entry
=
SET
y = x
Safety parameters
p9300 … p9399
p9500 … p9599
p10000 ... p10199
are valid after save;
STARTER issues a
message if a
POWER ON is
required
=
<1>
<1>
<1> Comparator, see [1021].
<2> Analog signal memory, see [1021].
<3> The target checksum must be equal to the actual check sum.
p9399
SI ref CRC P2
r9398
SI act CRC P2
SI ref CRC
p9729
SI act CRC
r9728
<3>
p0010 95
Quit Safety commissioning mode
=
Checksum check
for
Safety parameters
& &
<2>
Safety Integrated commissioning
p0010 = 95
<3>
SI enable fct P1
p9601 = 0
SI enable fct P2
p9801 = 0
SI Mtn enable P2
p9301 = 0
SI Mtn enable P1
p9501 = 0

Table of Contents

Other manuals for Siemens SINAMICS S110

Related product manuals