Siemens SINAMICS S110 - p4724[0...1] Trace average in the time range; Trace average; r4725[0...1] Trace, data type 1 traced; Trace rec type 1; r4726[0...1] Trace, data type 2 traced; Trace rec type 2; r4727[0...1] Trace, data type 3 traced; Trace rec type 3

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
List of parameters
1-456
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Index: [0] = Trace 0
[1] = Trace 1
Index: [0] = Trace 0
[1] = Trace 1
Index: [0] = Trace 0
[1] = Trace 1
Index: [0] = Trace 0
[1] = Trace 1
Index: [0] = Trace 0
[1] = Trace 1
p4724[0...1] Trace average in the time range / Trace average
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0000 bin 0001 bin 0000 bin
r4725[0...1] Trace, data type 1 traced / Trace rec type 1
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r4726[0...1] Trace, data type 2 traced / Trace rec type 2
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r4727[0...1] Trace, data type 3 traced / Trace rec type 3
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r4728[0...1] Trace, data type 4 traced / Trace rec type 4
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -