Value: 0: Run-time group 0
1: Run-time group 1
2: Run-time group 2
3: Run-time group 3
4: Run-time group 4
5: Run-time group 5
6: Run-time group 6
7: Run-time group 7
8: Run-time group 8
9: Run-time group 9
9999: Do not calculate
Description: Setting parameter for the run sequence of instance BSW 1 within the run-time group set in p20216.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantities X0 and X1 of instance NSW 0 of the numeric changeover switch.
Index: [0] = Input X0
[1] = Input X1
Description: Sets the signal source of the switch setting I of instance NSW 0 of the numeric changeover switch.
p20217 BSW 1 run sequence / BSW 1 RunSeq
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned16 Dynamic index: - Func. diagram: 7250
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 7999 590
p20218[0...1] CI: NSW 0 inputs / NSW 0 inputs
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / FloatingPoint32 Dynamic index: - Func. diagram: 7250
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 0
p20219 BI: NSW 0 switch setting I / NSW 0 sw_setting
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 7250
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0