Siemens SINAMICS S110 - p9552 SI Motion transition time STOP C to SOS (processor 1); SI Mtn t C­>SOS P1; p9553 SI Motion transition time STOP D to SOS (processor 1); SI Mtn t D­>SOS P1; p9554 SI Motion transition time STOP E to SOS (processor 1); SI Mtn t E­>SOS P1; p9555 SI Motion transition time STOP F to STOP B (processor 1); SI Mtn t F­>B P1

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameter
1-575
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Sets the transition time from STOP C to "Safe Operating Stop" (SOS).
Note: SOS: Safe Operating Stop
Description: Sets the transition time from STOP D to "Safe Operating Stop" (SOS).
Note: SOS: Safe Operating Stop
Description: Sets the transition time from STOP E to "Safe Operating Stop" (SOS).
Dependency: Refer to: p9354
Note: SOS: Safe Operating Stop
Description: Sets the transition time from STOP F to STOP B.
Dependency: Refer to: C01711
Description: Sets the delay time for the safe pulse suppression after STOP B.
In the case of encoderless motion monitoring functions with brake ramp monitoring (p9506 = 1), the parameter has
no effect.
p9552 SI Motion transition time STOP C to SOS (processor 1) / SI Mtn t C->SOS P1
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C2(95) Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: 2825
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [ms] 600000.00 [ms] 100.00 [ms]
p9553 SI Motion transition time STOP D to SOS (processor 1) / SI Mtn t D->SOS P1
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C2(95) Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: 2825
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [ms] 600000.00 [ms] 100.00 [ms]
p9554 SI Motion transition time STOP E to SOS (processor 1) / SI Mtn t E->SOS P1
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C2(95) Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [ms] 600000.00 [ms] 100.00 [ms]
p9555 SI Motion transition time STOP F to STOP B (processor 1) / SI Mtn t F->B P1
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C2(95) Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: 2825
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [ms] 600000.00 [ms] 0.00 [ms]
p9556 SI Motion pulse suppression delay time (processor 1) / SI Mtn IL t_del P1
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C2(95) Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: 2825
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [ms] 600000.00 [ms] 100.00 [ms]