Function diagrams
Setpoint channel
2-856
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-94 3030 – Main/supplementary setpoint, setpoint scaling, jogging
- 3030 -
Function diagram
87654321
DO: SERVO
SINAMICS S110
30.09.11 V04.04.00
Setpoint channel - Main/supplementary setpoint, setpoint scaling, jogging
r1077
r1073
r1078
+
+
Jog 1
r0898.8
Jog 2
r0898.9
fp_3030_98_eng.vsd
p1055
p1056
Suppl setp scal
(1)
p1076[C]
Main setp scal
(1)
p1071[C]
Main setpoint
(1024[0])
p1070[C]
Supplement setpoint
(0)
p1075[C]
p2901
Fixed value 2 [%]
p2900
Fixed value 1 [%]
0 0
0 1
1 0
1 1
n_set_1
Jog setpoint 1
-210 000.000...210 000.000 rpm
p1058[D] (100.000)
Jog setpoint 2
-210 000.000...210 000.000 rpm
p1059[D] (100.000)
[3040.1]
Keep old setpoint
<100>
Refer to [1020.7]
4000.00 μs
<100> Only if the function module “extended setpoint channel“ is activated (r0108.8 = 1).
[2501.3]