EasyManua.ls Logo

Siemens SINAMICS S110 - Fig. 2-94 3030 - Main;supplementary setpoint, setpoint scaling, jogging

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function diagrams
Setpoint channel
2-856
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-94 3030 – Main/supplementary setpoint, setpoint scaling, jogging
- 3030 -
Function diagram
87654321
DO: SERVO
SINAMICS S110
30.09.11 V04.04.00
Setpoint channel - Main/supplementary setpoint, setpoint scaling, jogging
r1077
r1073
r1078
+
+
Jog 1
r0898.8
Jog 2
r0898.9
fp_3030_98_eng.vsd
p1055
p1056
Suppl setp scal
(1)
p1076[C]
Main setp scal
(1)
p1071[C]
Main setpoint
(1024[0])
p1070[C]
Supplement setpoint
(0)
p1075[C]
p2901
Fixed value 2 [%]
p2900
Fixed value 1 [%]
0 0
0 1
1 0
1 1
n_set_1
Jog setpoint 1
-210 000.000...210 000.000 rpm
p1058[D] (100.000)
Jog setpoint 2
-210 000.000...210 000.000 rpm
p1059[D] (100.000)
[3040.1]
Keep old setpoint
<100>
Refer to [1020.7]
4000.00 μs
<100> Only if the function module “extended setpoint channel“ is activated (r0108.8 = 1).
[2501.3]
[2501.3]