EasyManua.ls Logo

Siemens SINAMICS S110 - r8512 CO: Data transfer 0 receive wordwise; Trans 0 recv word; r8513 CO: Data transfer 1 receive wordwise; Trans 1 recv word; r8514 CO: Data transfer 2 receive wordwise; Trans 2 recv word; r8515 CO: Data transfer 3 receive wordwise; Trans 3 recv word

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
List of parameters
1-496
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Displays the signals of the wordwise received data (process signal).
This signal value is interconnected and transferred via CI: p8502.
Dependency: Refer to: p8502
Description: Displays the signals of the wordwise received data (process signal).
This signal value is interconnected and transferred via CI: p8503.
Dependency: Refer to: p8503
Description: Displays the signals of the wordwise received data (process signal).
This signal value is interconnected and transferred via CI: p8504.
Dependency: Refer to: p8504
Description: Displays the signals of the wordwise received data (process signal).
This signal value is interconnected and transferred via CI: p8505.
Dependency: Refer to: p8505
r8512 CO: Data transfer 0 receive wordwise / Trans 0 recv word
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r8513 CO: Data transfer 1 receive wordwise / Trans 1 recv word
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r8514 CO: Data transfer 2 receive wordwise / Trans 2 recv word
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r8515 CO: Data transfer 3 receive wordwise / Trans 3 recv word
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]