Brake control
Function diagrams
2-833
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-73 2711 – Extended brake control, signal outputs (r0108.14 = 1)
- 2711 -
Function diagram
87654321
DO: SERVO
SINAMICS S110
30.10.08 V04.04.00
Braking control - Extended braking control, signal outputs (r0108.14 = 1)
1 = Command, open brake
r1229.1
Pulse enable from the brake control
r0899.14
Setpoint enable from the brake control
r0899.15
&
&
&
Brake does not close
&
&
0...10 000 ms
p1217 (100)
T0
0...10 000 ms
p1216 (100)
[2704.8]
Brake does not open
r1229.4
r1229.5
Close brake (internal)
[2707.8]
Close "normal" brake
1
Open brake (internal)
[2707.8]
T0
<1>
No OFF1
No OFF3
Pulse enable from the expanded brake control
r1229.3
&
1
<2>
<2>
1
0
1
0
1
0
1
1
0
1
Brake is being used
p1215 > 0
Brake with
feedback signal
p1275.5
[2814.2]
A07932
A07931
[2501.1]
[2503.3]
fp_2711_98_eng.vsd
Background
Refer to [1020.7]
Pulse enable, HW
1
0
Brake is being used
p1215 > 0
1
&
[2610.5]
[2610.8]
Coast down not active (r0899.4)
Enable operation (r0898.3)
Power-on inhibit (r0899.6)
[2704.8]
Close brake from standstill detection
Request pulse enable
[2707.1]
Close brake
From the standstill detection
[2503.7]
[2503.7]
[2501.7]
<3>
(1)
Brake feedb open
p1223
<4>
1 = Open holding brake
r0899.12
1 = Command, close holding brake
r0899.13
<5>
<1> This pulse enable path only works for operation with brake (p1215 > 0).
<2> For brakes with one single checkback signal, the inverted signal has to be interconnected to the BICO input for the second checkback. The switching times of the brake are set in p1216 and p1217.
<3> If an external motor holding brake is used, p1215 should be set to 3 and r1229.1 should be used as control signal.
<4> The internal signal comprises signals that lead to OFF1 or OFF3, e.g. BICO or fault response.
<5> If the function module "extended brake control" is active (r0108.14 = 1), r1229.1 should be interconnected as control signal.
Note: Braking signal diagnostic evaluation (p1278) is only relevant for SBC (Safe Brake Control) (controls the Safe Brake Relay).
(0)
Brake feedb closed
p1222
SET
(Q=1)
RESET
(Q=0)
Q
Q
[2503.3]
[2503.3]
[2503.3]
1
1
&