Parameter
List of parameters
1-146
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Displays the access authority at the digital outputs.
Bit = 1:
The control has access authority to the digital output via PROFIBUS or direct access.
Bit = 0:
The drive has access authority to the digital output or the digital input/output is not set as digital output or is not
available.
Dependency: Refer to: p0728, p0738, p0739, p0740, p0741, r0747, p0748
Note: The DI/DO must be connected as output (p0728).
DI/DO: Bidirectional Digital Input/Output
Description: Sets the signal source for terminal DI/DO 8 (X132.1).
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: Prerequisite: The DI/DO must be set as an output (p0728.8 = 1).
DI/DO: Bidirectional Digital Input/Output
Description: Sets the signal source for terminal DI/DO 9 (X132.2).
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: Prerequisite: The DI/DO must be set as an output (p0728.9 = 1).
DI/DO: Bidirectional Digital Input/Output
r0729 CU digital outputs access authority / CU DO acc_auth
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: 2030, 2031
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
08 DI/DO 8 (X132.1) High Low -
09 DI/DO 9 (X132.2) High Low -
10 DI/DO 10 (X132.3) High Low -
11 DI/DO 11 (X132.4) High Low -
16 DO 16 (X131.5) High Low -
p0738 BI: CU, signal source for terminal DI/DO 8 / CU S_src DI/DO 8
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 1510, 2030
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p0739 BI: CU, signal source for terminal DI/DO 9 / CU S_src DI/DO 9
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 1510, 2030,
2130, 2497, 2498
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0