Siemens SINAMICS S110 - p4812 Function generator physical address; FG phys address; p4813 Function generator physical address reference value; FG phys addr ref; p4815[0...2] Function generator drive number; FG drive number; p4816 Function generator output signal integer number scaling; FG outp integ scal

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameter
1-471
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Value: 0: Connection at connector output r4818
1: Connection at current setpoint after filter and r4818
2: Connection as disturbing torque and r4818
3: Connection at speed setpoint after filter and r4818
4: Connection at current setpoint before filter and r4818
5: Connection at speed setpoint before filter and r4818
6: Connection for free measurement function r4818 and r4834
99: Connection at physical address and r4818
Description: Sets the physical address where the function generator is to be connected.
Dependency: Only effective when p4810 = 99.
Description: Sets the reference value for 100 % for referred inputs.
Dependency: Only effective when p4810 = 99.
Description: Selects the required drive where the function generator is to be connected.
Index: [0] = First drive for connection
[1] = Second drive for connection
[2] = Third drive for connection
Dependency: Only effective when p4810 = 1, 2, 3, 4 or 5.
Note: For the function generator, only type SERVO, VECTOR or DC_CTRL type drives can be used.
Description: Sets the scaling for the integer number of the output signal for the function generator.
Dependency: Refer to: r4805, r4817
Note: The parameter can only be changed in the following operating states:
r4805 = 0, 4, 6
p4812 Function generator physical address / FG phys address
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0 4294967295 0
p4813 Function generator physical address reference value / FG phys addr ref
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
1.00 1000000.00 1.00
p4815[0...2] Function generator drive number / FG drive number
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0 65535 0
p4816 Function generator output signal integer number scaling / FG outp integ scal
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 4
Data type: Integer32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-2147483648 2147483647 0