Siemens SINAMICS S110 - p0795 CU digital inputs simulation mode; CU DI simulation; p0796 CU digital inputs simulation mode setpoint; CU DI simul setp

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
List of parameters
1-156
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Sets the simulation mode for digital inputs.
Dependency: The setpoint for the input signals is specified using p0796.
Refer to: p0796
Notice: If a digital input is used as signal source for the function "STO" (BI: p9620) then it is not permissible to select the
simulation mode and this is rejected.
Note: This parameter is not saved when data is backed-up (p0971, p0977).
DI: Digital Input
DI/DO: Bidirectional Digital Input/Output
Description: Sets the setpoint for the input signals in the digital input simulation mode.
p0795 CU digital inputs simulation mode / CU DI simulation
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 Dynamic index: - Func. diagram: 1510, 2020,
2030, 2031, 2100, 2120, 2130,
2131, 2132, 2133
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0000 0000 0000 0000 0000
0000 0000 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (X133.1) Simulation Terminal eval. -
01 DI 1 (X133.2) Simulation Terminal eval. -
02 DI 2 (X133.3) Simulation Terminal eval. -
03 DI 3 (X133.4) Simulation Terminal eval. -
08 DI/DO 8 (X132.1) Simulation Terminal eval. -
09 DI/DO 9 (X132.2) Simulation Terminal eval. -
10 DI/DO 10 (X132.3) Simulation Terminal eval. -
11 DI/DO 11 (X132.4) Simulation Terminal eval. -
16 DI 16 (X130.1) Simulation Terminal eval. -
17 DI 17 (X130.2) Simulation Terminal eval. -
18 DI 18 (X130.4) Simulation Terminal eval. -
19 DI 19 (X130.5) Simulation Terminal eval. -
20 DI 20 (X131.1) Simulation Terminal eval. -
21 DI 21 (X131.2) Simulation Terminal eval. -
22 DI 22 (X131.4) Simulation Terminal eval. -
p0796 CU digital inputs simulation mode setpoint / CU DI simul setp
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 Dynamic index: - Func. diagram: 1510, 2020,
2030, 2031, 2100, 2120, 2130,
2131, 2132, 2133
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0000 0000 0000 0000 0000
0000 0000 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (X133.1) High Low -
01 DI 1 (X133.2) High Low -
02 DI 2 (X133.3) High Low -
03 DI 3 (X133.4) High Low -
08 DI/DO 8 (X132.1) High Low -
09 DI/DO 9 (X132.2) High Low -
10 DI/DO 10 (X132.3) High Low -
11 DI/DO 11 (X132.4) High Low -
16 DI 16 (X130.1) High Low -
17 DI 17 (X130.2) High Low -