List of parameters
Parameter
1-423
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Motor moment of inertia determined by the motor data identification.
This motor moment of inertia can be changed after the identification and accepted in p0341 with p1910/p1960 = -3.
Dependency: Refer to: p0341, p1960, r1969
Description: Load moment of inertia determined by the motor data identification.
This load moment of inertia can be changed after the identification and accepted in p1498 with p1910/p1960 = -3.
Dependency: Refer to: p0342, p1498, p1960, r1969
Note: For p1910/p1960 = -3, p0342 is set to 1 (ratio between the total and motor).
Description: Speed at the start of field weakening determined by the motor data identification.
This start speed can be changed after the identification and accepted in p0348 with p1910/p1960 = -3.
Dependency: Refer to: p0348, p1910, p1960
Description: Stator resistance determined by the motor data identification.
This stator resistance can be changed after the identification and accepted in p0350 with p1910/p1960 = -3.
Dependency: Refer to: p0350, p1910, r1912
p3041 MotId moment of inertia identified / M_inertia ident
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: 25_1 Unit selection: p0100
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.000000 [kgm²] 100000.000000 [kgm²] 0.000000 [kgm²]
p3042 MotId load moment of inertia identified / Load mom ident
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: 25_1 Unit selection: p0100
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00000 [kgm²] 100000.00000 [kgm²] 0.00000 [kgm²]
p3049[0...n] MotId Speed at start of field weakening identified / ident
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: FloatingPoint32 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00000 [rpm] 210000.00000 [rpm] 0.00000 [rpm]
p3050[0...n] MotorId stator resistance identified / R_stator ident
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: FloatingPoint32 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor identification Units group: 16_1 Unit selection: p0349
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00000 [ohm] 2000.00000 [ohm] 0.00000 [ohm]