EasyManua.ls Logo

Siemens SINAMICS S110 - r9711[0...1] SI Motion diagnostics result list 2; SI Mtn res_list 2

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
List of parameters
1-588
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Dependency: Refer to: C01711
Note: SBR: Safe Brake Ramp (safe brake ramp monitoring)
SLP: Safely-Limited Position
SLS: Safely-Limited Speed
SOS: Safe Operating Stop
Description: Displays result list 2 that, for the crosswise data comparison between the monitoring channels, led to the fault.
Index: [0] = Result list, second channel
[1] = Result list, drive
Dependency: Refer to: C01711
Note: SCA: Safe Cam
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
03 Actual value > lower limit, SLP1 Yes No -
04 Actual value > upper limit, SLP2 Yes No -
05 Actual value > lower limit, SLP2 Yes No -
06 Actual value > upper limit, SLS1 Yes No -
07 Actual value > lower limit, SLS1 Yes No -
08 Actual value > upper limit, SLS2 Yes No -
09 Actual value > lower limit, SLS2 Yes No -
10 Actual value > upper limit, SLS3 Yes No -
11 Actual value > lower limit, SLS3 Yes No -
12 Actual value > upper limit, SLS4 Yes No -
13 Actual value > lower limit, SLS4 Yes No -
16 Actual value > upper limit, SAM/SBR Yes No -
17 Actual value > lower limit, SAM/SBR Yes No -
18 Actual value > upper limit SDI positive Yes No -
19 Actual value > lower limit SDI positive Yes No -
20 Actual value > upper limit SDI negative Yes No -
21 Actual value > lower limit SDI negative Yes No -
r9711[0...1] SI Motion diagnostics result list 2 / SI Mtn res_list 2
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Actual value > upper limit SCA1+ Yes No -
01 Actual value > lower limit, SCA1+ Yes No -
02 Actual value > upper limit SCA1- Yes No -
03 Actual value > lower limit, SCA1- Yes No -
04 Actual value > upper limit SCA2+ Yes No -
05 Actual value > lower limit, SCA2+ Yes No -
06 Actual value > upper limit SCA2- Yes No -
07 Actual value > lower limit, SCA2- Yes No -
08 Actual value > upper limit SCA3+ Yes No -
09 Actual value > lower limit, SCA3+ Yes No -
10 Actual value > upper limit SCA3- Yes No -
11 Actual value > lower limit, SCA3- Yes No -
12 Actual value > upper limit SCA4+ Yes No -
13 Actual value > lower limit, SCA4+ Yes No -
14 Actual value > upper limit SCA4- Yes No -
15 Actual value > lower limit, SCA4- Yes No -
16 Actual value > upper limit, SSM+ Yes No -
17 Actual value > lower limit, SSM+ Yes No -
18 Actual value > upper limit, SSM- Yes No -
19 Actual value > lower limit, SSM- Yes No -
20 Actual value > upper limit, modulo Yes No -
21 Actual value > lower limit, modulo Yes No -

Table of Contents