Parameter
List of parameters
1-74
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Note: The value depends on the device type and the selected rated voltage p0210.
For booksize units, the following applies:
The undervoltage threshold can be reduced with p0278.
Description: If the DC link voltage exceeds the threshold specified here, the drive unit is tripped due to DC link overvoltage.
Dependency: Refer to: F30002
Description: Selects the motor type or start to read in the motor parameters for a motor with DRIVE-CLiQ (p0300 = 10000).
For p0300 < 10000 the following applies:
The first digit of the parameter value always defines the general motor type and corresponds to the third-party
motor belonging to a motor list:
1 = Rotating induction motor
2 = Rotating synchronous motor
The type information must be entered to filter motor-specific parameters and to optimize the operating characteris-
tics and behavior. For example, for synchronous motors, power factor (p0308) is neither used nor displayed (in the
BOP/AOP).
Value: 0: No motor
1: Induction motor (rotating)
2: Synchronous motor (rotating, permanent-magnet)
104: 1PH4 induction motor
107: 1PH7 induction motor
108: 1PH8 induction motor
111: Induction motor (rotary) for OEMs
200: 1PH8 synchronous motor
206: 1FT6 synchronous motor
207: 1FT7 synchronous motor
222: Synchronous motor (rotary) for OEMs
236: 1FK6 synchronous motor
237: 1FK7 synchronous motor
444: Synchronous motor (linear) for OEMs
10000: Motor with DRIVE-CLiQ
10001: Motor with DRIVE-CLiQ 2nd data set
Dependency: When the motor type is changed, the code number in p0301 may be reset to 0.
If p0300 is changed during quick commissioning (p0010 = 1), then the matching technological application (p0500) is
automatically pre-assigned. This does not occur when commissioning the motor (p0010 = 3). If p0300 = 10000 is
written for a parameter download, p0500 is pre-assigned with DRIVE-CLiQ corresponding to the motor type.
Refer to: p0301
Caution: If a catalog motor is selected (p0300 >= 100) and an associated motor code number (p0301), then the parame-
ters,that are associated with this list cannot be changed (write protection). The write protection is canceled if the
motor type p0300 is set to a non-Siemens motor that matches p0301 (e.g. p0300 = 2 for p0301 = 2xxxx). Write pro-
tection is automatically canceled when the results of motor data identification are copied to the motor parameters.
r0297 DC link voltage overvoltage threshold / Vdc U_upper_thresh
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dynamic index: - Func. diagram: 8750, 8760,
8850, 8864, 8950, 8964
P-Group: Converter Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
p0300[0...n] Motor type selection / Mot type sel
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C2(1, 3) Calculated: - Access level: 1
Data type: Integer16 Dynamic index: MDS, p0130 Func. diagram: 6310
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 10001 0