List of parameters
Parameter
1-119
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Re bit 14, 15:
r0481.14 = 1 and r0481.15 = 0 can have one of the following causes:
- the encoder is parked.
- the encoder is de-activated.
- the encoder is being commissioned.
- no parameterized encoder available.
- encoder data set is being changed over.
r0481.14 = 1 and r0481.15 = 1 has the following significance:
An encoder error has occurred and the encoder position actual value (Gn_XIST1) is invalid.
Description: Displays the encoder actual position value Gn_XIST1 according to PROFIdrive.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Note: - this value is reset if necessary when the "parking encoder" (r0481.14) function is de-selected.
- in this value, the measuring gear (p0432, p0433) is only taken into account when the position tracking is activated
(p0411.0 = 1).
Description: Displays the encoder actual position value Gn_XIST2 according to PROFIdrive.
Recommend.: Possible causes of the error codes:
Error code 4097 and 4098: Defective Control Unit hardware.
Error codes 4099 and 4100: Too many measuring pulses have occurred.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Notice: The encoder position actual value must be requested using the encoder control word Gn_STW.13.
Note: - in this value, the measuring gear (p0432, p0433) is only taken into account when the position tracking is activated
(p0411.0 = 1).
- if GxZSW.15 = 1 (r0481), then an error code with the following significance is located in Gx_XIST2 (r0483):
1: Encoder fault.
2: Possible position shift in Gx_XIST1.
3: Encoder parking not possible.
4: Abort, reference mark search.
5: Abort, retrieve reference value.
6: Abort, flying measurement.
7: Abort, retrieve measured value.
8: Abort, absolute value transfer.
3841: Function not supported.
r0482[0...2] CO: Encoder actual position value Gn_XIST1 / Enc Gn_XIST1
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: 1580, 2450,
4010, 4704, 4735, 4740
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r0483[0...2] CO: Encoder actual position value Gn_XIST2 / Enc Gn_XIST2
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: 1580, 2450,
4010, 4704
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1