EasyManua.ls Logo

Siemens SINAMICS S110 - r9724 SI Motion crosswise comparison clock cycle; SI Mtn CDC clk cyc; r9725[0...2] SI Motion, diagnostics STOP F; SI Mtn Diag STOP F; p9726 SI Motion, user agreement selection;de-selection; SI Mtn UserAgr sel

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameter
1-593
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Displays the crosswise comparison clock cycle.
The value indicates the clock cycle time with which each individual CDC value is compared between the two moni-
toring channels.
Dependency: Refer to: p9500
Note: Crosswise comparison clock cycle = monitoring clock cycle (p9500) * number of data to be crosswise compared
CDC: Crosswise Data Check
Description: Re index 0:
Displays the message value that resulted in the STOP F on the drive.
Value = 0:
The Control Unit signaled a STOP F.
Value = 1 ... 999:
Number of the incorrect date in the crosswise data comparison between the monitoring channels.
Value >= 1000:
Additional diagnostic values of the drive.
Re index 1:
Displays the value of the Control Unit that resulted in the STOP F.
Re index 2:
Displays the value from the second channel that resulted in the STOP F.
Index: [0] = Message value for CDC
[1] = Control Unit CDC act value
[2] = Components CDC act val
Dependency: Refer to: C01711
Note: The significance of the individual message values is described in message C01711.
CDC: Crosswise Data Check
Description: Setting to select and de-select the user agreement.
Value: 0: [00 hex] De-select user agreement
172: [AC hex] Select user agreement
Dependency: Refer to: r9727
r9724 SI Motion crosswise comparison clock cycle / SI Mtn CDC clk cyc
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [ms] - [ms] - [ms]
r9725[0...2] SI Motion, diagnostics STOP F / SI Mtn Diag STOP F
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p9726 SI Motion, user agreement selection/de-selection / SI Mtn UserAgr sel
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: - Access level: 4
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0000 hex 00AC hex 0000 hex