Fig. 2-179 8565 – Drive Data Sets (DDS)
- 8565 -
Function diagram
87654321
fp_8565_98_eng.vsd
DO: SERVO
SINAMICS S110
07.11.11 V04.04.00
Data sets - Drive Data Sets, DDS
Not relevant
Refer to [1020.7]
(0)
Select DDS bit 0
p0820[C]
Drive 1
MDS (Motor Data Set)
EDS (Encoder Data Set)
DDS (Drive Data Set)
p0186[0...n] (MDS number)
p0187[0...n] (enc 1 EDS number)
<1> A BICO interconnection to a parameter which is part of a drive data set always influences the currently effective data set.
Copy DDS, source
p0819[0] (0)
Copy DDS, target
p0819[1] (1)
Copy DDS, start
p0819[2] (0)
DDS number
p0180 (1)
DDS1
DDS0
<1>
DDS selected
r0837.0
r0837
DDS effective
r0051.0
r0051
r0837.1
r0051.1
A07530 "Drive data set does not exist"
r0838
r0838[0] Motor data set MDS selected
r0838[1] Encoder 1 encoder data set EDS selected
r0838[2] Encoder 2 encoder data set EDS selected
r0049
r0049[0] Motor data set MDS effective
r0049[1] Encoder 1 encoder data set EDS effective
r0049[2] Encoder 2 encoder data set EDS effective
p0188[0...n] (enc 2 EDS number)