Function diagrams
Setpoint channel
2-858
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-96 3050 – Skip frequency bands and speed limitations
- 3050 -
Function diagram
87654321
fp_3050_98_eng.vsd
DO: SERVO
SINAMICS
30.09.11 V04.04.00
Setpoint channel - Skip frequency bands and speed limitations
<1> A suppression speed of "0" de-activates the suppression speed bandwidth.
<2> The setting range of p1082 is limited to n_max_mot.
<3> If the drive is not stopped via the input setpoint, but via controlled intervention, the lower hysteresis branch is relevant after a subsequent run-up.
<100> For SERVO, the following applies: Only if the function module "Extended setpoint channel" is activated (r0108.8 = 1). For r0108.8 = 0, [3095] applies for the generation of the speed limits.
w
n_skip 2
0.000...210 000.000 rpm
p1092[D] (0.000)
n_skip 3
0.000...210 000.000 rpm
p1093[D] (0.000)
n_skip 1
0.000...210 000.000 rpm
p1091[D] (0.000)
n_skip 4
0.000...210 000.000 rpm
p1094[D] (0.000)
n_skip bandwidth
0.000...210 000.000 rpm
p1101[D] (0.000)
[3020.6]
[3060.4]
[3070.4]
[3040.8]
(1083)
p1085[C]
p1083
n_limit pos
0.000...210 000.000 rpm
p1083[D] (210 000.000)
Maximum speed
0...210 000.000 rpm
p1082[D] (n_max_Mot)
(1086)
p1088[C]
p1086
n_limit neg
-210 000.000...0.000 rpm
p1086[D] (-210 000.000)
r1114
Setpt after limit
Reference value
for the ramp-
function generator
<1> <1> <1>
<1>
Max
1000.00 μs
Min
<2>
<3>
[5030.5]
[5210.1]
[8010.2]
<100>
0
0
Refer to [1020.7]
4000.00 μs
r1084
n_limit pos eff
r1087
n_limit neg eff
[5030.5]
[5210.1]
[8010.2]
w
w
w
w
w
w
w
-1 -1 -1 -1
y
x
-1
Minimum speed
0.00...19 500.00 rpm
p1080[D] (0.00)
r1112
y
(1086)
p1052[C]
(1083)
p1051[C]
p1083
p1086
-1
r1119
RFG setpt at input
[3060.1]
[3070.1]
0
0
Maximum
limiting
active
[3080.4]
1