Parameter
List of parameters
1-380
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Sets the signal source for the software limit switch minus.
Dependency: Refer to: p2579, p2580, p2581, p2582
Refer to: A07469, A07477, A07479, F07481
Notice: A change to the software limit switch becomes immediately effective.
If the software limit switch is changed, then this results in the positions in the traversing blocks being checked.
Note: The following applies for the setting of the software limit switch:
Software limit switch minus < software limit switch plus
Description: Sets the signal source for the software limit switch plus.
Dependency: Refer to: p2578, p2580, p2581, p2582
Refer to: A07470, A07478, A07480, F07482
Notice: A change to the software limit switch becomes immediately effective.
If the software limit switch is changed, then this results in the positions in the traversing blocks being checked.
Note: The following applies for the setting of the software limit switch:
Software limit switch minus < software limit switch plus
Description: Sets the software limit switch in the negative direction of travel.
Dependency: Refer to: p2578, p2579, p2581, p2582
Description: Sets the software limit switch in the positive direction of travel.
p2578 CI: EPOS software limit switch minus signal source / SW limSw Min S_src
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Integer32 Dynamic index: - Func. diagram: 3630
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 2580[0]
p2579 CI: EPOS software limit switch plus signal source / SW limSwPlus S_src
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Integer32 Dynamic index: - Func. diagram: 3630
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 2581[0]
p2580 CO: EPOS software limit switch minus / SW limSwitch minus
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed: U, T Calculated: - Access level: 1
Data type: Integer32 Dynamic index: - Func. diagram: 3630
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-2147482648 [LU] 2147482647 [LU] -2147482648 [LU]
p2581 CO: EPOS software limit switch plus / SW lim switch plus
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed: U, T Calculated: - Access level: 1
Data type: Integer32 Dynamic index: - Func. diagram: 3630
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-2147482648 [LU] 2147482647 [LU] 2147482647 [LU]