Siemens SINAMICS S110 - p2578 CI: EPOS software limit switch minus signal source; SW limSw Min S_src; p2579 CI: EPOS software limit switch plus signal source; SW limSwPlus S_src; p2580 CO: EPOS software limit switch minus; SW limSwitch minus; p2581 CO: EPOS software limit switch plus; SW lim switch plus

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
List of parameters
1-380
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Sets the signal source for the software limit switch minus.
Dependency: Refer to: p2579, p2580, p2581, p2582
Refer to: A07469, A07477, A07479, F07481
Notice: A change to the software limit switch becomes immediately effective.
If the software limit switch is changed, then this results in the positions in the traversing blocks being checked.
Note: The following applies for the setting of the software limit switch:
Software limit switch minus < software limit switch plus
Description: Sets the signal source for the software limit switch plus.
Dependency: Refer to: p2578, p2580, p2581, p2582
Refer to: A07470, A07478, A07480, F07482
Notice: A change to the software limit switch becomes immediately effective.
If the software limit switch is changed, then this results in the positions in the traversing blocks being checked.
Note: The following applies for the setting of the software limit switch:
Software limit switch minus < software limit switch plus
Description: Sets the software limit switch in the negative direction of travel.
Dependency: Refer to: p2578, p2579, p2581, p2582
Description: Sets the software limit switch in the positive direction of travel.
p2578 CI: EPOS software limit switch minus signal source / SW limSw Min S_src
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Integer32 Dynamic index: - Func. diagram: 3630
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 2580[0]
p2579 CI: EPOS software limit switch plus signal source / SW limSwPlus S_src
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Integer32 Dynamic index: - Func. diagram: 3630
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 2581[0]
p2580 CO: EPOS software limit switch minus / SW limSwitch minus
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed: U, T Calculated: - Access level: 1
Data type: Integer32 Dynamic index: - Func. diagram: 3630
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-2147482648 [LU] 2147482647 [LU] -2147482648 [LU]
p2581 CO: EPOS software limit switch plus / SW lim switch plus
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed: U, T Calculated: - Access level: 1
Data type: Integer32 Dynamic index: - Func. diagram: 3630
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-2147482648 [LU] 2147482647 [LU] 2147482647 [LU]