List of parameters
Parameter
1-245
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Sets the adaptation factor after the adaptation range (> p1457) to additionally adapt the P gain of the speed/velocity
controller.
Dependency: Refer to: p1455, p1456, p1457, p1458
Description: Sets the P gain of the speed controller before the adaptation speed range (0 ... p1464). This value corresponds to
the basic setting of the P gain of the speed controller without adaptation (p1461 = 100 %).
Dependency: Refer to: p1461, p1464, p1465
Note: When automatically calculating the speed controller, only the motor moment of inertia is taken into account (p0341).
For higher load moments of inertia (p0342 > 1 or p1498 > 0), you are advised to check the speed controller gain.
Description: Sets the P gain of the speed controller for the upper adaptation speed range (> p1465). The entry is made referred
to the P gain for the lower adaptation speed range of the speed controller (% referred to p1460).
Dependency: Refer to: p1460, p1464, p1465
Note: When automatically calculating the speed controller, only the motor moment of inertia is taken into account (p0341).
For higher load moments of inertia (p0342 > 1 or p1498 > 0), you are advised to check the speed controller gain.
Description: Sets the integration time of the speed controller before the adaptation speed range (0 ... p1464).
This value corresponds to the basic setting of the integral time of the speed controller without adaptation (p1461 =
100 %).
Dependency: Refer to: p1463, p1464, p1465
p1459[0...n] Adaptation factor, upper / Adapt_factor upper
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: 5050
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.0 [%] 200000.0 [%] 100.0 [%]
p1460[0...n] Speed controller P gain adaptation speed, lower / n_ctrl Kp n lower
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: CALC_MOD_CON Access level: 2
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: 5040, 5042
P-Group: Closed-loop control Units group: 17_1 Unit selection: p0505
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.000 [Nms/rad] 999999.000 [Nms/rad] 0.300 [Nms/rad]
p1461[0...n] Speed controller Kp adaptation speed, upper scaling / n_ctrl Kp n upper
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: 5050
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.0 [%] 200000.0 [%] 100.0 [%]
p1462[0...n] Speed controller integral time adaptation speed lower / n_ctrl Tn n lower
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: CALC_MOD_CON Access level: 2
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: 1700, 5040,
5042, 6040
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.00 [ms] 100000.00 [ms] 20.00 [ms]