EasyManua.ls Logo

Siemens SINAMICS S110 - Fig. 2-168 8010 - Speed signals 1

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Signals and monitoring functions
Function diagrams
2-939
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-168 8010 – Speed signals 1
- 8010 -
Function diagram
87654321
fp_8010_98_eng.vsd
DO: SERVO
SINAMICS S110
30.09.11 V04.04.00
Signals and monitoring functions - Speed signals 1
r2169
n_act smooth signal
[8011.1]
[8012.5]
[8013.1]
0.00...60 000.00 rpm
p2162[D] (600.00)
0.00...300.00 rpm
p2140[D] (90.00)
n_Hysterrese 2
n_thresh val 2
0.00...210 000.00 rpm
p2155[D] (900.00)
0...1 000 000 ms
p2153 (0)
[3050.8]
[3095.7]
0
1
0
1
0
1
n_thresh val 1
0.00...210 000.00 rpm
p2141[D] (5.00)
0.000...300.000 rpm
p2142[D] (2.00)
n_hysteresis 1
|n_act| > n_max
r2197.6
|n_act| p2155
r2197.1 [2534.3]
f or n-comparison value
reached/exceeded
r2199.1 [2537.3]
T0
0...10 000 ms
p2156[D] (0)
[2534.3]
r0063
n_act smooth
[4710.7]
n
n
0
Smoothing
n_thresh val 3
0.00...210 000.00 rpm
p2161[D] (5.00)
0
1
|n_act| < p2161
r2199.0 [2537.3]
r1087
n_limit neg eff
r1084
n_limit pos eff
0.00...300.00 rpm
p2150[D] (2.00)
n_hysteresis 3
F07901 "motor overspeed"
250.00 μs 4000.00 μs

Table of Contents

Other manuals for Siemens SINAMICS S110

Related product manuals