Parameter
List of parameters
1-478
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
--> p5009 = 51 ... 53: fault values if the operation was not able to be successfully completed.
--> carry out a POWER ON (switch-off/switch-on).
Value: 0: No function
1: Reset
2: Set invalid
3: Reserved
5: Set valid
20: Operation successfully completed.
40: Operation running
51: Function not supported
52: File access unsuccessful
53: Operation unsuccessful
Note: Help for fault value = 51 ... 53:
- repeat the operation.
Description: Setting to enable/inhibit spindle commissioning.
Value: 0: Spindle commissioning enabled
1: Spindle commissioning inhibited
Note: The parameter is automatically set to a value of 1 after exiting commissioning (p0009 = 0).
Description: Displays the status for write protection of adjustable parameters.
Note: Write protection can be activated/deactivated via p7760 on the Control Unit.
Description: Setting for activating/de-activating the write protection for adjustable parameters.
Value: 0: Inactive
1: Active
Note: The following parameters are excluded from the write protection:
- p0003 (BOP access level)
- p0971 (drive object save parameters)
- p0977 (save all parameters)
- p3950 (service parameters)
p5016 Enable spindle commissioning / Enable comm
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C2, T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
r7760 Write protection status / Write prot stat
All objects Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Write protection active -
p7761 Write protection / Write protection
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0