Parameter
List of parameters
1-138
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Defines the rated overtemperature of the stator winding referred to the ambient temperature.
Dependency: For 1LA5 and 1LA7 motors (refer to p0300), the parameter is pre-set as a function of p0307 and p0311.
Refer to: p0625
Note: When quick commissioning is exited with p3900 > 0, then the parameter is reset if a catalog motor has not been
selected (refer to p0300).
Description: Defines the rated overtemperature of the squirrel cage rotor referred to ambient temperature.
Dependency: For 1LA5 and 1LA7 motors (refer to p0300), the parameter is pre-set as a function of p0307 and p0311.
Refer to: p0625
Note: When quick commissioning is exited with p3900 > 0, then the parameter is reset if a catalog motor has not been
selected (refer to p0300).
Description: Displays the ambient temperature of the motor temperature model.
Description: Displays the stator core temperature of the motor temperature model.
Description: Displays the stator winding temperature of the motor temperature model.
p0627[0...n] Motor overtemperature, stator winding / Mot T_over stator
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C2(3), U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: MDS, p0130 Func. diagram: 8016
P-Group: Motor Units group: 21_2 Unit selection: p0505
Not for motor type: PEM, REL, FEM Scaling: - Expert list: 1
Min Max Factory setting
20 [K] 200 [K] 80 [K]
p0628[0...n] Motor overtemperature rotor winding / Mot T_over rotor
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C2(3), U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: MDS, p0130 Func. diagram: 8016
P-Group: Motor Units group: 21_2 Unit selection: p0505
Not for motor type: PEM, REL, FEM Scaling: - Expert list: 1
Min Max Factory setting
20 [K] 200 [K] 100 [K]
r0630[0...n] Motor temperature model ambient temperature / MotTMod T_amb.
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dynamic index: MDS, p0130 Func. diagram: 8016
P-Group: Motor Units group: 21_1 Unit selection: p0505
Not for motor type: PEM, REL, FEM Scaling: p2006 Expert list: 1
Min Max Factory setting
- [°C] - [°C] - [°C]
r0631[0...n] Motor temperature model, stator core temperature / MotTMod T_core
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dynamic index: MDS, p0130 Func. diagram: 8016
P-Group: Motor Units group: 21_1 Unit selection: p0505
Not for motor type: PEM, REL, FEM Scaling: p2006 Expert list: 1
Min Max Factory setting
- [°C] - [°C] - [°C]
r0632[0...n] Motor temperature model, stator winding temperature / MotTMod T_copper
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dynamic index: MDS, p0130 Func. diagram: 8016
P-Group: Motor Units group: 21_1 Unit selection: p0505
Not for motor type: PEM, REL, FEM Scaling: p2006 Expert list: 1
Min Max Factory setting
- [°C] - [°C] - [°C]