List of parameters
Parameter
1-263
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Sets the denominator natural frequency for current setpoint filter 1 (PT2, general filter).
Dependency: Current setpoint filter 1 is activated via p1656.0 and parameterized via p1657 ... p1661.
Description: Sets the denominator damping for current setpoint filter 1.
Dependency: Current setpoint filter 1 is activated via p1656.0 and parameterized via p1657 ... p1661.
Description: Sets the numerator natural frequency for current setpoint filter 1 (general filter).
Dependency: Current setpoint filter 1 is activated via p1656.0 and parameterized via p1657 ... p1661.
Description: Sets the numerator damping for current setpoint filter 1.
Dependency: Current setpoint filter 1 is activated via p1656.0 and parameterized via p1657 ... p1661.
Description: Sets the current setpoint filter 2 as low pass (PT2) or as extended general 2nd-order filter.
Value: 1: Low pass: PT2
2: General 2nd-order filter
Dependency: Current setpoint filter 2 is activated via p1656.1 and parameterized via p1662 ... p1666.
p1658[0...n] Current setpoint filter 1 denominator natural frequency / I_set_filt 1 fn_n
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: 5710, 6710
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.5 [Hz] 16000.0 [Hz] 1999.0 [Hz]
p1659[0...n] Current setpoint filter 1 denominator damping / I_set_filt 1 D_n
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: 5710, 6710
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.001 10.000 0.700
p1660[0...n] Current setpoint filter 1 numerator natural frequency / I_set_filt 1 fn_z
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: 5710, 6710
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.5 [Hz] 16000.0 [Hz] 1999.0 [Hz]
p1661[0...n] Current setpoint filter 1 numerator damping / I_set_filt 1 D_z
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: 5710, 6710
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.000 10.000 0.700
p1662[0...n] Current setpoint filter 2 type / I_set_filt 2 Typ
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: DDS, p0180 Func. diagram: 5710, 6710
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
1 2 1