Description: The inhibit list contains parameters that should be withdrawn from the automatic motor and closed-loop control
parameter calculation (p0340, p0578).
Value: 0: No parameter
348: Speed at the start of field weakening Vdc = 600 V
600: Motor temperature sensor
640: Current limit
1082: Maximum speed
1441: Actual speed smoothing time
1460: Speed controller P gain
1462: Speed controller integral time
1470: Speed controller P gain, encoderless
1472: Speed controller integral time, encoderless
1520: Torque limit upper/motoring
1521: Torque limit lower/regenerative
1530: Power limit motoring
1531: Power limit regenerative
1590: Flux controller P gain
1592: Flux controller integral time
1656: Activates current setpoint filter
2141: Speed threshold 1
2142: Hysteresis speed 1
Note: p0570 defines the number of entries (starting at index 0) for which the inhibit should apply. p0572 can be used to
define for which drive data sets the inhibit list should apply.
If a motor data set is entered into a parameter number, then this is not overwritten as soon as only one drive data
set refers to the motor data set (p0186).
Description: Enable ID as to whether the parameters of the inhibit list p0571 should be overwritten when calculating the motor
and closed-loop control parameters for the particular drive data set (index = DDS).
Value: 0: No
1: Yes
Note: 0: The automatic calculation (p0340, p0578) also overwrites the parameters of list p0571.
1: The automatic calculation (p0340, p0578) does not overwrite the parameters of list p0571.
Description: Setting to inhibit the calculation of reference parameters (e.g. p2000) when automatically calculating the motor and
closed-loop control parameters (p0340, p3900).
p0571[0...49] Inhibit list, motor/closed-loop control parameter calculation / Inhib list calc
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: - Access level: 2
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Applications Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 2142 0
p0572[0...n] Activate inhibit list / Act inhib list
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: - Access level: 2
Data type: Integer16 Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Applications Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p0573 Inhibit automatic reference value calculation / Inhibit calc
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: - Access level: 2
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Applications Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0