List of parameters
Parameter
1-85
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Sets the motor cooling system used.
Value: 0: Non-ventilated
1: Forced cooling
2: Liquid cooling
4: Non-ventilated and internal fan
5: Forced cooling and internal fan
6: Liquid cooling and internal fan
128: No fan
Dependency: For 1LA5 and 1LA7 motors (refer to p0300), the parameter is pre-set as a function of p0307 and p0311.
Caution: When selecting a catalog motor (p0301), this parameter is automatically pre-assigned and is write protected. Infor-
mation in p0300 should be carefully observed when removing write protection.
Note: The parameter influences the thermal 3-mass motor model.
1LA1 and 1LA8 motors are characterized by the fact that they have an internal rotor fan. This "internal cooling" lies
within the motor frame and is not visible. Air is not directly exchanged with the motor ambient air. For 1PQ8 motors,
p0335 should be set to 5 as these motors are force-ventilated motors.
1LA7 motors, frame size 56 are operated without fan.
Description: Displays the rated frequency of the motor.
For p0310 > 0, this value is displayed.
Dependency: Refer to: p0311, p0314
Note: For p0310 = 0 or for synchronous motors, the rated motor frequency r0336 is calculated from the rated speed and
the pole pair number.
For p0310 > 0, this value is displayed (not for synchronous motors).
Description: Displays the rated EMF of the motor.
Note: EMF: Electromagnetic force
p0335[0...n] Motor cooling type / Motor cooling type
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C2(1, 3), T Calculated: - Access level: 1
Data type: Integer16 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: PEM, REL, FEM Scaling: - Expert list: 1
Min Max Factory setting
0 128 0
r0336[0...n] Actual rated motor frequency / Mot f_rated act
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [Hz] - [Hz] - [Hz]
r0337[0...n] Rated motor EMF / Mot EMF_rated
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
- [Vrms] - [Vrms] - [Vrms]