List of parameters
Parameter
1-497
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Setting for saving the actual configuration of the Advanced Operator Panel (AOP).
Description: Displays the ACX file saved in the appropriate directory in the non-volatile memory.
Note: For a value = 9999999, the following applies: The read operation is still running.
Description: Displays the ACX file saved in the appropriate directory in the non-volatile memory.
Note: For a value = 9999999, the following applies: The read operation is still running.
Description: Displays the ACX file saved in the appropriate directory in the non-volatile memory.
Note: For a value = 9999999, the following applies: The read operation is still running.
p8550 AOP LOCAL/REMOTE / AOP LOCAL/REMOTE
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 4
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0000 0000 0000 1001 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 LOCAL save Yes No -
01 Start in LOCAL Yes No -
02 Change in oper. Yes No -
03 OFF acts like OFF1 Yes No -
04 OFF acts like OFF2 Yes No -
05 OFF acts like OFF3 Yes No -
06 Reserved Yes No -
07 CW/CCW active Yes No -
08 Jog active Yes No -
09 Save speed setpoint Yes No -
14 Inhibit operation Yes No -
15 Inhibit parameterization Yes No -
r8571[0...39] Macro Binector Input (BI) / Macro BI
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r8572[0...39] Macro Connector Inputs (CI) for speed setpoints / Macro CI n_set
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r8573[0...39] Macro Connector Inputs (CI) for torque setpoints / Macro CI M_set
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -