List of parameters
Parameter
1-65
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Displays the bootloader version.
Dependency: Refer to: r0018, r0128, r0148, r0198
Note: Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description: Displays the BIOS and EEPROM data version.
r0198[0]: BIOS version
r0198[1]: EEPROM data version
Dependency: Refer to: r0018, r0128, r0148, r0197
Note: Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description: Freely assignable name for a drive object.
In the commissioning software, this name cannot be entered using the expert list, but is specified in the configura-
tion assistant. The object name can be subsequently modified in the Project Navigator using standard Windows
resources.
Note: The parameter is not influenced by setting the factory setting.
Description: Displays the unique code number of the power unit.
Note: r0200 = p0201: No power unit found
For parallel circuit configurations, the parameter index is assigned to a power unit.
r0197 Bootloader vers / Bootloader vers
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r0198[0...1] BIOS/EEPROM data version / BIOS/EEPROM vers
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p0199[0...24] Drive object name / DO name
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C1 Calculated: - Access level: 2
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 65535 0
r0200[0...n] Power unit code number actual / PU code no. act
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: PDS Func. diagram: -
P-Group: Converter Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -