List of parameters
Parameter
1-659
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Setting parameter for the run sequence of instance OR 1 within the run-time group set in p20052.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantities I0, I1, I2, I3 of instance OR 2 of the OR function block.
Index: [0] = Input I0
[1] = Input I1
[2] = Input I2
[3] = Input I3
Description: Display parameter for binary quantity Q = I0 | I1 | I2 | I3 of instance OR 2 of the OR function block.
p20053 OR 1 run sequence / OR 1 RunSeq
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned16 Dynamic index: - Func. diagram: 7212
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 32000 70
p20054[0...3] BI: OR 2 inputs / OR 2 inputs
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 7212
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
r20055 BO: OR 2 output Q / OR 2 output Q
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: 7212
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -