EasyManua.ls Logo

Siemens SINAMICS S110 - Fig. 2-117 4015 - Position controller (r0108.3 = 1)

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function diagrams
Position control
2-882
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-117 4015 – Position controller (r0108.3 = 1)
- 4015 -
Function diagram
87654321
fp_4015_98_eng.vsd
DO: SERVO
SINAMICS S110
30.09.11 V04.04.00
Position control - Position controller (r0108.3 = 1)
1000.00 μs
t
x,y x
y
x
t
y
s_set_filt T
0.00...1000.00 [ms]
p2533[D] (0.00)
d
dt
Pre-control
balancing
Simulation of the build-up of the
pre-control speed
+
n_pre-ctrl factor
0.00...200.00 [%]
p2534[D] (0.00)
n_pre-ctrl filter PT1
0.00...100.00 [ms]
p2536[D] (0.00)
Tn
0.00...100000.00 [ms]
p2539[D] (0.00)
r2559
LR_output I-comp
r2558
LR_output P-comp
Kp
0.000...300.000 [1000/min]
p2538[D] (1.000)
+
r2562
n_set total
+
r2556
s_set after interp
r2557
LR_input sys dev
d
dt
r2564
M_pre-ctrl value
-1
LR_output limit
0.000...210000.000 [rpm]
p2540[D] (210000.000)
p2540
LR_output lim src
(p2540)
p2541
s_act
(r2521[0])
p2532
v_set
(0/r2666)
p2531
s_set
(0/r2665)
p2530
Adaptation
(1)
p2537
1 = Position controller output limited
r2526.6
r2560
n_setp
r2561
n_pre-ctrl value
Tn
P
[4025.1]
n_ffCtrl flt t_dead
0.00...2.00
p2535[D] (0.00)
t_sample int ctrl
[4010.8]
[4010.8]
LU/rev LU/mm
(r2524)
p2555
p2513
p2512,
p2730
[4020.1]
<1>
<1> When the "basic positioner" function module (r0108.4 = 1) is active, these binector/connector inputs are supplied by default with values from this module.
The second value specifies this assignment.
<1>
[4020.1]
[4025.1]
[3635.7]
[3635.7]
<2> For p2534 > 0 % the following applies: A deadtime of two position controller clock cycles is additionally effective.
<3> For p2534 = 0 % the following applies: Pre-control balancing is not effective.
+
<2>
<3>
r2565
Following err act
<2>
r2566
M_prectr M_inertia
p2567[D]
2
<4> Only if the “extended brake control“ function module is active (r0108.14 = 1).
[3080.3]
&
[4010.8]
p2549
(r0899.2)
Enable 1
p2550
(0/1)
Enable 2
<1>
p1152
(r0899.15)
Setpt 2 enable
[2503.7]
Pos act val valid
r2526.0
1 = Position control active
r2526.3
[3635.1]
<4>
[2503.7]

Table of Contents