Siemens SINAMICS S110 - p9905 Device specialization; Specialization; p9910 Transfer additional components into the target topology; Transfer comp; p9915 DRIVE-CLiQ data transfer error shutdown threshold master; DLQ fault master; p9916 DRIVE-CLiQ data transfer error shutdown threshold slave; DLQ fault slave

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
List of parameters
1-614
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: With p9905 = 1, the serial numbers and the hardware versions of all of the components are transferred from the
actual topology into the target topology and a new comparison is started..
For this device specialization, the components of the target topology may only differ from those of the actual topol-
ogy by the serial numbers.
With p9905 = 2, the serial numbers, the hardware versions and the order numbers of all of the components are
transferred from the actual topology into the target topology and a new comparison is started..
For this device specialization, the components of the target topology may only differ from those of the actual topol-
ogy by the serial numbers and order numbers.
Note: p9905 is automatically set to 0 at the end of the operation.
In order to permanently accept the data, it is necessary to save in a non-volatile fashion (p0977).
Description: Transfer additional inserted DRIVE-CLiQ components into the target topology and add the appropriate drive objects
to the project.
Value: 0: No selection
1: Drive object type SERVO
2: Drive object type VECTOR
3: SINAMICS GM (DFEMV & VECTORMV)
4: SINAMICS SM (AFEMV & VECTORMV)
5: SINAMICS GL (VECTORGL)
6: SINAMICS SL (VECTORSL)
Description: Only for internal Siemens service purposes.
Description: Only for internal Siemens service purposes.
p9905 Device specialization / Specialization
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: C1(1) Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Topology Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 2 0
p9910 Transfer additional components into the target topology / Transfer comp
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: C1(1) Calculated: - Access level: 1
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Topology Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 6 0
p9915 DRIVE-CLiQ data transfer error shutdown threshold master / DLQ fault master
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: C1(1) Calculated: - Access level: 4
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Topology Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0000 hex 0007 07FF hex 0007 02FF hex
p9916 DRIVE-CLiQ data transfer error shutdown threshold slave / DLQ fault slave
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: C1(1) Calculated: - Access level: 4
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Topology Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0000 hex 0007 07FF hex 0007 02FF hex