Parameter
List of parameters
1-614
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: With p9905 = 1, the serial numbers and the hardware versions of all of the components are transferred from the
actual topology into the target topology and a new comparison is started..
For this device specialization, the components of the target topology may only differ from those of the actual topol-
ogy by the serial numbers.
With p9905 = 2, the serial numbers, the hardware versions and the order numbers of all of the components are
transferred from the actual topology into the target topology and a new comparison is started..
For this device specialization, the components of the target topology may only differ from those of the actual topol-
ogy by the serial numbers and order numbers.
Note: p9905 is automatically set to 0 at the end of the operation.
In order to permanently accept the data, it is necessary to save in a non-volatile fashion (p0977).
Description: Transfer additional inserted DRIVE-CLiQ components into the target topology and add the appropriate drive objects
to the project.
Value: 0: No selection
1: Drive object type SERVO
2: Drive object type VECTOR
3: SINAMICS GM (DFEMV & VECTORMV)
4: SINAMICS SM (AFEMV & VECTORMV)
5: SINAMICS GL (VECTORGL)
6: SINAMICS SL (VECTORSL)
Description: Only for internal Siemens service purposes.
Description: Only for internal Siemens service purposes.
p9905 Device specialization / Specialization
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: C1(1) Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Topology Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 2 0
p9910 Transfer additional components into the target topology / Transfer comp
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: C1(1) Calculated: - Access level: 1
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Topology Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 6 0
p9915 DRIVE-CLiQ data transfer error shutdown threshold master / DLQ fault master
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: C1(1) Calculated: - Access level: 4
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Topology Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0000 hex 0007 07FF hex 0007 02FF hex
p9916 DRIVE-CLiQ data transfer error shutdown threshold slave / DLQ fault slave
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: C1(1) Calculated: - Access level: 4
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Topology Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0000 hex 0007 07FF hex 0007 02FF hex