List of parameters
Parameter
1-255
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Danger: For p1400.4 = 0 (torque limiting, upper/lower) the following applies:
Negative values resulting from the signal source and scaling can cause the motor to accelerate in an uncontrolled
manner.
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Sets the signal source for the scaling of the lower torque limit or the regenerative torque limit in p1523.
Dependency: p1400.4 = 0: upper/lower
p1400.4 = 1: motoring / regenerating
Danger: For p1400.4 = 0 (torque limiting, upper/lower) the following applies:
Positive values resulting from the signal source and scaling can cause the motor to accelerate in an uncontrolled
manner.
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Sets the power limit when motoring.
Dependency: Refer to: p0500, p1531
Description: Sets the regenerative power limit.
Dependency: Refer to: p0500, p1530
Description: Sets the torque offset for the torque limit.
Dependency: Refer to: p1520, p1521, p1522, p1523, p1528, p1529
p1529[0...n] CI: Torque limit lower/regenerative scaling / M_max low/gen scal
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 1610, 3617,
5620, 5630
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 1525[0]
p1530[0...n] Power limit motoring / P_max mot
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated:
CALC_MOD_LIM_REF
Access level: 2
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: 5640
P-Group: Closed-loop control Units group: 14_5 Unit selection: p0505
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.00 [kW] 100000.00 [kW] 0.00 [kW]
p1531[0...n] Power limit regenerative / P_max gen
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated:
CALC_MOD_LIM_REF
Access level: 2
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: 5640
P-Group: Closed-loop control Units group: 14_5 Unit selection: p0505
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
-100000.00 [kW] -0.01 [kW] -0.01 [kW]
p1532[0...n] CO: Torque limit offset / M_max offset
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: 5620, 5630,
5650, 7010, 8012
P-Group: Closed-loop control Units group: 7_1 Unit selection: p0505
Not for motor type: REL Scaling: p2003 Expert list: 1
Min Max Factory setting
-100000.00 [Nm] 100000.00 [Nm] 0.00 [Nm]