EasyManua.ls Logo

Siemens SINAMICS S110 - Fig. 2-60 2522 - Status word, speed controller

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function diagrams
Internal control/status words
2-818
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-60 2522 – Status word, speed controller
- 2522 -
Function diagram
87654321
fp_2522_98_eng.vsd
DO: SERVO
SINAMICS S110
26.07.10 V04.04.00
Internal control/status words - Status word, speed controller
1
2
3
4
5
6
7
8
9
10
11
0
Bit No.
12
13
14
15
-
Servo
-
From torque limiting [5610.4]
From the setpoint, n-ctrl [5030.8]
<1> From the speed controller [5210.3]
From torque limiting [5610.4]
From torque limiting [5610.4]
Sensorless operation
[2520.7]
-
r1407.8
r1407.9
r1407.11
r1407.1
1 = Torque control
r1406.12
r1407.7
From the changeover, closed-loop control types [5060.5]
<1> From the speed controller [5210.8]
From the speed controller [5040.7]
<1> From the speed controller [5210.8]
From the speed controller [5040.7]
1 = V/f control active
Status word, speed controller
1 = Sensorless operation active
1 = Closed-loop torque control active
1 = Closed-loop speed control active
Reserved
1 = Speed controller, I component held
1 = Speed controller, I component set
1 = Torque limit reached
1 = Torque limiting, upper, active
1 = Torque limiting, lower, active
1 = Droop enabled
1 = Speed setpoint limited
1 = Ramp-function generator set
1 = Sensorless operation due to a fault
Reserved
1 = I/f control active
-
r1407.11
r1407.5
r1407.6
r1407.2
<1> Only for servo control without encoder.
-
-
To the speed actual value and pole position
sensing, motor encoder (encoder 1)
[4710.4]
Ramp-function generator tracking [3080.1]
“Traveling blocks“ mode [3616.1]
Speed controller [5040.7][5042.5]
Motor locked/stalled [8012.5]
r1407.13
1000.00 μs
r1407.0
p0115[1] (Motor Module)
p1190 > 0 (interconnected)
p1191 > 0 (interconnected)
PcCtrl active
Mot-ID
OFF1
1
OFF3
STOP2
&
Motion-based
PolID
r1407
ZSW n_ctrl
&

Table of Contents

Other manuals for Siemens SINAMICS S110