Siemens SINAMICS S110 - Fig. 2-57 2503 - Status word, sequence control

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Internal control/status words
Function diagrams
2-815
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-57 2503 – Status word, sequence control
- 2503 -
Function diagram
87654321
fp_2503_98_eng.vsd
DO: SERVO
SINAMICS S110
31.10.08 V04.04.00
Internal control/status words - Status word, sequence control
11
12
13
14
15
<1> The drive object is ready to accept data.
PROFIdrive bit
Bit No.
10
9
8
7
6
5
4
3
0
1
2
From the control unit [2610]
From the control unit [2610]
From the control unit [2610]
From the control unit [2610]
From the control unit [2610]
From the control unit [2610]
From the control unit [2610.4]
2000.00 μs
r0899.0
r0899.1
r0899.4
r0899.5
r0899.11
r0899.12
r0899.2
r0899.6
r0899.9
1 = Ready to operate (DC link loaded, pulses blocked)
1 = Ready to power-up
Status word sequence control
1 = Operation enabled (drive follows n_set)
1 = Jog active
1 = No coast down active (OFF2 inactive)
1 = No fast stop active (OFF3 inactive)
1 = Power-on inhibit active
1 = Drive ready
1 = Controller enable
1 = Control requested <1>
Reserved
1 = Pulses enabled
1 = Open holding brake (only for booksize units when the brake is
connected to the power unit)
1 = Command, close holding brake
1 = Enable setpoint from the brake control
1 = Pulse enable from the brake control
Bit 9 = 1 --> Ready to exchange process data
r0899.13
From the basic brake control (p0108.14 = 0) [2701.8]
From the extended brake control/standstill detection (p0108.14 = 1) [2711.8]
r0899.14
r0899.15
From the control unit [2610] r0899.3
<2> If „Safe Brake Control" (SBC) is activated and selected, the brake is no longer controlled via this signal.
r0899.7
r0899.8From the control unit [2610]
(1)
2. OFF2
p0845[C]
(1)
2. OFF3
p0849[C]
OFF1
OFF2
OFF3
1
Enable
internal
missing
or
fault with
this reaction
&
From the basic brake control (p0108.14 = 0) [2701.8]
From the extended brake control/standstill detection (p0108.14 = 1) [2711.8]
[4015.1]
[4015.1]
[2701.1]
[2701.1]
r0899
ZSW sequence ctrl
<2>
From the extended brake control/standstill detection (p0108.14 = 1) [2711.8]
From the extended brake control/standstill detection (p0108.14 = 1) [2711.8]
<3> These signals are only relevant if the "extended brake control" function module is active (r0108.14 = 1).
<3>
<3>