Siemens SINAMICS S110 - r0196[0...255] DRIVE-CLiQ component status; DLQ comp status

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
List of parameters
1-64
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Notice: This information represents the characteristics/features of the power unit firmware. It does not provide informa-
tion/data about the characteristics/features of the hardware (e.g. bit 06 = 1 means that although the firmware sup-
ports "liquid cooling", a power unit with liquid cooling does not have to be used).
Note: Re bit 09:
The Motor Module supports the internal armature short-circuit. The function is internally required for voltage protec-
tion (p1231 = 3).
Re bit 10:
The Motor Module supports the autonomous internal voltage protection. If the voltage protection function is inter-
nally activated (p1231 = 3) the Motor Module decides autonomously - using the DC link voltage - as to whether the
short-circuit is activated.
Re bit 23:
The component supports the detection of current actual values (and the detection of valve close durations) with
double clocking and phase shift.
Description: Displays the status of DRIVE-CLiQ components.
r0196[0...1]: Not used
r0196[2]: Status of DRIVE-CLiQ component with component number 2
...
r0196[255]: Status of DRIVE-CLiQ component with component number 255
Note: Structure of status value: Bits 31 ... 08, 07, 06 ... 04, 03 ... 00
Re Bit 31 ... 08: Reserved
Re Bit 07: 1: Part of target topology, 0: Only in actual topology
Re Bit 06 ... 04: 1: Active, 0: Inactive or parked
Re bit 03 ... 00:
0: Component data not available.
1: Power-up, acyclic DRIVE-CLiQ communication (LED = orange).
2: Ready for operation, cyclic DRIVE-CLiQ communication (LED = green).
3: Alarm (LED = green).
4: Fault (LED = red).
5: Detection via LED and ready for operation (LED = green/orange).
6: Detection via LED and alarm (LED = green/orange).
7: Detection via LED and fault (LED = red/orange).
8: Downloading firmware (LED = green/red at 0.5 Hz).
9: Firmware downloading completed, Waiting for POWER ON (LED = green/red at 2.0 Hz).
23 Current measurement oversampling avail-
able
Yes No -
24 Keep the relevant data for parking available Yes No -
25 Internal fan operating hours counter avail-
able
Yes No -
26 Software gating unit in the CU is supported Yes No -
27 Current controller dynamics higher Yes No -
r0196[0...255] DRIVE-CLiQ component status / DLQ comp status
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -