Parameter
List of parameters
1-142
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Value: 0: Measurement with handshake
1: Measurement without handshake
Note: During measurement without a handshake, the probe may have a higher evaluation frequency.
The setting "Measurement without handshake" must be supported by the higher-level control. This setting cannot
be used for SIMOTION D with integrated SINAMICS or with CX32.
Description: Displays the control word for the function "central measuring probe evaluation".
Description: Displays the measuring time for a rising edge at the digital input for the "central measuring probe evaluation" func-
tion.
The measuring time is specified as 16-bit value with a resolution of 0.25 µs.
r0686[0]: Measuring time, rising edge measuring probe 1
r0686[1]: Measuring time, rising edge measuring probe 2
r0686[2]: Measuring time, rising edge measuring probe 3
r0686[3]: Measuring time, rising edge measuring probe 4
r0686[4]: Measuring time, rising edge measuring probe 5
r0686[5]: Measuring time, rising edge measuring probe 6
r0686[6]: Measuring time, rising edge measuring probe 7
r0686[7]: Measuring time, rising edge measuring probe 8
r0685 Central measuring probe, control word display / Cen meas STW disp
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Falling edge, measuring probe 1 Yes No -
01 Falling edge, measuring probe 2 Yes No -
02 Falling edge, measuring probe 3 Yes No -
03 Falling edge, measuring probe 4 Yes No -
04 Falling edge, measuring probe 5 Yes No -
05 Falling edge, measuring probe 6 Yes No -
06 Falling edge, measuring probe 7 Yes No -
07 Falling edge, measuring probe 8 Yes No -
08 Rising edge, measuring probe 1 Yes No -
09 Rising edge, measuring probe 2 Yes No -
10 Rising edge, measuring probe 3 Yes No -
11 Rising edge, measuring probe 4 Yes No -
12 Rising edge, measuring probe 5 Yes No -
13 Rising edge, measuring probe 6 Yes No -
14 Rising edge, measuring probe 7 Yes No -
15 Rising edge, measuring probe 8 Yes No -
r0686[0...7] CO: Central measuring probe, measuring time rising edge / CenMeas t_meas 0/1
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -