Parameters for data sets
Parameter
1-743
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
p1233[0...n] DC braking time / DCBRK time
p1234[0...n] Speed at the start of DC braking / DCBRK n_start
p1236[0...n] Ext. armature short-cct., contactor feedback signal monit. time / ASC ext t_monit
p1237[0...n] External armature short-circuit, delay time when opening / ASC ext t_wait
p1909[0...n] Motor data identification control word / MotID STW
p1958[0...n] Rotating measurement ramp-up/ramp-down time / Rot meas t_r up/dn
p1959[0...n] Rotating measurement configuration / Rot meas config
p1980[0...n] PolID technique / PolID technique
p1981[0...n] PolID distance max / PolID distance max
p1982[0...n] PolID selection / PolID selection
p1991[0...n] Motor changeover, angular commutation correction / Ang_com corr
p1993[0...n] PolID motion-based current / PolID I mot_bas
p1994[0...n] PolID motion-based rise time / PolID T mot_bas
p1995[0...n] PolID motion-based gain / PolID kp mot_bas
p1996[0...n] PolID motion-based integral time / PolID Tn mot_bas
p1997[0...n] PolID motion-based smoothing time / PolID t_sm mot_bas
p3049[0...n] MotId Speed at start of field weakening identified / ident
p3050[0...n] MotorId stator resistance identified / R_stator ident
p3054[0...n] MotId rotor resistance identified / R_rotor ident
p3056[0...n] MotId stator leakage inductance identified / L_stator leak
p3058[0...n] MotId rotor leakage inductance identified / L_rotor leak
p3060[0...n] MotId magnetizing inductance identified / MotId Lh ident
1.3.5 Parameters for power unit data sets (PDS)
The following list contains the parameters that are dependent on the power unit data sets.
Product: S110, Version: 4402100, Language: eng, Type: PDS
p0121[0...n] Power unit component number / PU comp_no
r0127[0...n] Power unit version EPROM data / PU EPROM version
r0128[0...n] Power unit, firmware version / PU FW version
r0200[0...n] Power unit code number actual / PU code no. act
p0201[0...n] Power unit code number / PU code no
r0203[0...n] Actual power unit type / PU actual type
r0204[0...n] Power unit hardware properties / PU HW property
p0251[0...n] Operating hours counter power unit fan / PU fan t_oper
Note:
References: /FH3/ SINAMICS S110 Function Manual
Chapter "Data Sets"