List of parameters
Parameter
1-221
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Sets the signal source for the command "open brake".
Dependency: Refer to: p1215, p1221, r1229, p1277
Description: Sets the threshold value for the command "open brake".
Dependency: Refer to: p1220, r1229, p1277
Description: Sets the signal source for the feedback signal "brake closed".
For motor holding brakes with feedback signal, the signal "brake closed" can be activated using p1275.5 = 1.
Dependency: Refer to: p1223, p1275
Note: 1 signal: Brake closed.
When braking with 1 feedback signal, the inverted feedback signal is connected to the BICO input for the second
feedback signal (p1223).
For r1229.5 = 1, OFF1/OFF3 are suppressed to prevent the drive accelerating by a load that drives the motor -
whereby OFF2 remains effective.
Description: Sets the signal source for the feedback signal "brake open".
For motor holding brakes with feedback signal, the signal "brake open" can be activated using p1275.5 = 1.
Dependency: Refer to: p1222, p1275
p1220 CI: Open motor holding brake, signal source, threshold / Open brake thresh
SERVO_S110-CAN
(Extended brk),
SERVO_S110-DP
(Extended brk),
SERVO_S110-PN
(Extended brk)
Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dynamic index: - Func. diagram: 2707
P-Group: Functions Units group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 1
p1221 Open motor holding brake, threshold / Open brake thresh
SERVO_S110-CAN
(Extended brk),
SERVO_S110-DP
(Extended brk),
SERVO_S110-PN
(Extended brk)
Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dynamic index: - Func. diagram: 2707
P-Group: Functions Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [%] 200.00 [%] 0.00 [%]
p1222 BI: Motor holding brake feedback signal brake closed / Brake feedb closed
SERVO_S110-CAN
(Extended brk),
SERVO_S110-DP
(Extended brk),
SERVO_S110-PN
(Extended brk)
Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 2711
P-Group: Functions Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p1223 BI: Motor holding brake feedback signal brake open / Brake feedb open
SERVO_S110-CAN
(Extended brk),
SERVO_S110-DP
(Extended brk),
SERVO_S110-PN
(Extended brk)
Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 2711
P-Group: Functions Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 1