EasyManua.ls Logo

Siemens SINAMICS S110 - Fig. 2-125 4740 - Probe evaluation, measured value memory, encoders 1... 2

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Encoder evaluation
Function diagrams
2-891
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-125 4740 – Probe evaluation, measured value memory, encoders 1 ... 2
- 4740 -
Function diagram
87654321
fp_4740_98_eng.vsd
DO: SERVO
SINAMICS S110
17.07.09 V04.04.00
Encoder evaluation - Measuring probe evaluation, measured value memory, encoders 1 ... 2
p0490.8
Measuring probe evaluation
STW for encoder n
Gn_STW [4720]
r0487[n-1].0
Gn_XIST2
for function No. = 1
Gn_XIST2
for function No. = 2
Gn_XIST2
for function No. = 3
Gn_XIST2
for function No. = 4
xy
Store
xy
Store
xy
Store
xy
Store
<1>
4 measured value memory
Up to 4 measuring functions can be simultneously active; the measured value
memory is read out using a handshaking technique according to [4720], [4730].
Index [n-1] --> encoder n (n = 1, 2)
Index [0] --> encoder 1
Index [1] --> encoder 2
&
&
&
&
r0487[n-1].1
r0487[n-1].3
r0487[n-1].2
r0487[n-1].4
r0487[n-1].7
&
Q
D
Q
D
Q
D
Q
D
Selecting the function to be activated
Store
D memory
element
Activate selected function
(no measuring probe for encoder n)
0
Measuring
probes
positions to
the encoder
interface
[4704.3]
<3>
<3> All other bits of the encoder control word must be 0.
r0483[n-1]
Position actual value 1
from encoder n
[4704.8]
Refer to [1020.7]
PROFIdrive sampling time
NOTE: SINAMICS S110 supports only one encoder. This encoder may be parameterized as encoder 1 or encoder 2.
"Fast inputs"
From the
digital
inputs/
outputs
p0490.10
p0490.9
DI10_probe
(X132.3)
[2031.4]
DI9_probe
(X132.2)
[2030.4]
DI8_probe
(X132.1)
[2030.4]
1
0
1
1
0
1
1
0
1
p0490.11
DI11_probe
(X132.4)
[2031.4]
1
0
1
Measuring probe 2 input
0...7
p0489[n-1] (0)
Measuring probe 1 deflected
to Gn_ZSW9 [4730.2]
0
0
1
2
3
4
5
6
x=
Measuring probe 1 deflected
to Gn_ZSW8 [4730.2]
Measuring probe 1 input
0...7
p0488[n-1] (0)
7
0
1
2
3
7
0
1
2
3
4
5
6
7

Table of Contents