Parameter
List of parameters
1-132
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Value: 1: %
2: 1 referred, no dimensions
3: bar
4: °C
5: Pa
6: ltr/s
7: m³/s
8: ltr/min
9: m³/min
10: ltr/h
11: m³/h
12: kg/s
13: kg/min
14: kg/h
15: t/min
16: t/h
17: N
18: kN
19: Nm
20: psi
21: °F
22: gallon/s
23: inch³/s
24: gallon/min
25: inch³/min
26: gallon/h
27: inch³/h
28: lb/s
29: lb/min
30: lb/h
31: lbf
32: lbf ft
Dependency: Only units of parameters with unit group 9_1 can be changed over using this parameter.
Refer to: p0596
Description: Sets the reference quantity for the technological units. When changing over using changeover parameter 595 to
absolute units, all of the parameters involved refer to the reference quantity.
Dependency: Refer to: p0595
Description: Sets the sensor to monitor the motor temperature.
Value: 0: No sensor
1: Temperature sensor via encoder 1
10: Temperature sensor via a BICO interconnection
11: Temperature sensor via Motor Module / CU terminals
p0596 Reference quantity, technological units / Ref tech units
SERVO_S110-CAN
(Tech_ctrl),
SERVO_S110-DP
(Tech_ctrl),
SERVO_S110-PN
(Tech_ctrl)
Can be changed: T Calculated: - Access level: 1
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.01 340.28235E36 1.00
p0600[0...n] Motor temperature sensor for monitoring / Mot temp_sensor
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C2(3), U, T Calculated: CALC_MOD_ALL Access level: 2
Data type: Integer16 Dynamic index: MDS, p0130 Func. diagram: 8016
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 11 1